Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

Author:

Deleu Marine12,Dagassan Dorothea3,Berg Isabelle4,Bize Julie1,Dula Karl5,Lenoir Vincent2,Ott Barbara6,Ott Julien G.7,Verdun Francis R.1,Weber Robert8,Ziglinas Panagiotis9,Zingariello Cesare2,Sans Merce Marta2

Affiliation:

1. Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland

2. Department of Radiology, University Hospital of Geneva, Geneva, Switzerland

3. University Center of Dental Medicine Basel, Center for Dental Imaging, University of Basel, Basel, Switzerland

4. University hospital of Basel, Basel, Switzerland

5. University of Bern, Bern, Switzerland

6. Radiation Protection Division, Federal office of Public Health, Bern, Switzerland

7. HNO-Zentrum, Bern, Switzerland

8. Division of Medical Radiation Physics, Inselspital, Bern, Switzerland

9. Praxisklinik, Basel, Switzerland

Abstract

Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (PKA). Results: 227 answers were collected (38% of all centers). Third quartile of PKA values were obtained for five dental indications: 662 mGy cm² for wisdom tooth, 683 mGy cm² for single tooth implant treatment, 542 mGy cm² for tooth position anomalies, 569 mGy cm² for pathological dentoalveolar modifications, and 639 mGy cm² for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and PKA were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3