Detection Method of Partial Discharge on Transformer and Gas-Insulated Switchgear: A Review

Author:

Faizol Zulbirri1,Zubir Farid2ORCID,Saman Norhafezaidi Mat3ORCID,Ahmad Mohd Hafizi3,Rahim Mohamad Kamal A.4,Ayop Osman4,Jusoh Muzammil5ORCID,Majid Huda A.6ORCID,Yusoff Zubaida7ORCID

Affiliation:

1. Department of Communication Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia

2. Wireless Communication Centre, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia

3. Institute of High Voltage & High Current, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia

4. Advanced RF & Microwave Research Group (ARFMRG), Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia

5. Faculty of Electronic Engineering & Technology, UniMAP Pauh Putra Main Campus, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia

6. Faculty of Engineering Technology, Pagoh Higher Education Hub, Universiti Tun Hussein Onn Malaysia, Pagoh 84600, Johor, Malaysia

7. Faculty of Engineering, Multimedia University, Persiaran Multimedia, Cyberjaya 63100, Selangor, Malaysia

Abstract

The detection of partial discharge (PD) activities in high-voltage equipment can be conducted according to several mechanisms of signal detection, including electromagnetic wave signal detection, acoustic signal detection, chemical reactions, electrical signal detection, and optical emission detection. Recently, multiple methods of detection and localization of partial discharge activities, which occurred in power transformers and gas-insulated switchgear (GIS), have been proposed to monitor the health condition of high-voltage equipment, especially when the awareness regarding preventive maintenance has been emphasized at the industrial level and among electrical providers. In aligning the needs of the industrial sector and the improvement of PD-detection methods, this manuscript focuses on reviewing the current practice methods for the detection and localization of PD signals in high-voltage equipment, comparing their efficacy, and summarizing the future direction of research work-related methods of PD detection. The comparative reviews are discussed in terms of the mechanism of PD signal detection, indication parameters, calibration techniques, and the advantages and limitations of each method of PD measurement in detail.

Funder

Higher Institution Centre of Excellence (HICOE), Ministry of Higher Education Malaysia, Wireless Communication Centre (WCC), Universiti Teknologi Malaysia

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3