The Importance of Boundary Conditions and Failure Criterion in Finite Element Analysis Accuracy—A Comparative Assessment of Periodontal Ligament Biomechanical Behavior

Author:

Moga Radu-Andrei1ORCID,Olteanu Cristian Doru2,Delean Ada Gabriela1

Affiliation:

1. Department of Cariology, Endodontics and Oral Pathology, School of Dental Medicine, University of Medicine and Pharmacy Iuliu Hatieganu, Str. Motilor 33, 400001 Cluj-Napoca, Romania

2. Department of Orthodontics, School of Dental Medicine, University of Medicine and Pharmacy Iuliu Hatieganu, Str. Avram Iancu 31, 400083 Cluj-Napoca, Romania

Abstract

(1) Background: Herein, finite element analysis (FEA) of the periodontal ligament (PDL) was used to assess differences between Tresca (T-non-homogenous) and Von Mises (VM-homogenous) criterion, by simulating a 0–8 mm periodontal breakdown under five orthodontic movements (extrusion, intrusion, rotation, tipping, and translation) and three loads (0.6, 1.2, and 2.4 N). Additionally, we addressed the issues of proper boundary condition selection for more than 1 N loads and correlated the results with the maximum hydrostatic pressure (MHP) and available knowledge, evaluating ischemic and resorptive risks for more than 1 N orthodontic loads. (2) Methods: Eighty-one models of the second lower premolar (nine patients) with intact and 1–8 mm reduced periodontia were created. The assumed boundary conditions were isotropy, homogeneity, and linear elasticity. A total of 486 FEA simulations were performed in Abaqus. (3) Results: Both criteria displayed similar qualitative results, with T being quantitatively 15% higher and better suited. The assumed boundary conditions seem to be correct up to 2.4 N of the applied load. (4) Conclusions: Both criteria displayed constant deformations and displacements manifested in the same areas independently of the load’s amount, the only difference being their intensity (doubling—1.2 N; quadrupling—2.4 N). Moreover, 2.4 N seems safe for intact periodontium, while, after a 4 mm loss (seen as the reference point), a load of more than 1 N seems to have significant ischemic and resorptive risks.

Publisher

MDPI AG

Reference50 articles.

1. Moga, R.-A., Olteanu, C.D., and Delean, A.G. (2024). Investigating the Ability of the Tooth and Surrounding Support Tissues to Absorb and Dissipate Orthodontic Loads during Periodontal Breakdown—Finite Elements Analysis. Appl. Sci., 14.

2. Pérez-González, A., Iserte-Vilar, J.L., and González-Lluch, C. (2011). Interpreting finite element results for brittle materials in endodontic restorations. Biomed. Eng. Online, 10.

3. Stress Induced in the Periodontal Ligament under Orthodontic Loading (Part I): A Finite Element Method Study Using Linear Analysis;Hemanth;J. Int. Oral Health,2015

4. Stress Induced in Periodontal Ligament under Orthodontic Loading (Part II): A comparison of Linear versus Non-Linear Fem Study;Hemanth;J. Int. Oral Health,2015

5. Orthodontically induced root resorption: A critical analysis of finite element studies’ input and output;Roscoe;Am. J. Orthod. Dentofac. Orthop.,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3