Bypass Configurations of Membrane Humidifiers for Water Management in PEM Fuel Cells

Author:

Vu Hoang Nghia1ORCID,Trinh Dinh Hoang1,Truong Le Tri Dat1,Yu Sangseok2

Affiliation:

1. Department of Mechanical Engineering, Graduate School, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea

2. School of Mechanical Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea

Abstract

Water management is an important criterion in the operation of proton-exchange membrane fuel cells to maintain the high performance and reliability of the system. The water content in the cathode air that is supplied to the cathode channel contributes to the membrane humidification and the transport of protons inside the membrane structure. In automotive applications, the supply air is typically driven through an external membrane humidifier to absorb more moisture from the recirculated cathode exhaust. In the literature, humidifiers and fuel cell stacks have been separately investigated without considering whole-system configurations for water management. This study investigates changes in the cathode air characteristics through a membrane humidifier and compares two configurations using a humidifier bypass of the supply flow and exhaust flow to adjust the cathode inlet air relative humidity. Each component in the system was modeled using mathematical relations and converted into blocks of inputs and outputs in MATLAB/Simulink for simulation. The bypass valve was demonstrated to effectively reduce the relative humidity of the supply air from the saturation rate to above 60%, with a bypass fraction of up to 0.6 in both configurations. These adjustments provide system flexibility to accommodate load changes and prevent flooding in the stack channels. Bypassing the supply air through the humidifier effectively maintained consistent cathode inlet humidity across a wide operational range. A 0.4 bypass fraction on the supply side sustained a relative humidity of around 80% for the whole range of operating flow rates. In contrast, the exhaust-side bypass had a smaller impact, and the relative humidity of the cathode air was reduced when the flow rate and bypass fraction increased. This study further supports the control system design to regulate the bypass fraction according to load transients.

Funder

National Research Foundation of Korea

Korea Institute of Energy Technology Evaluation and Planning

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3