Abstract
The activated sludge respiration inhibition test and the luminescent bacteria test with Vibrio fischeri are important bacterial test systems for evaluation of the toxicity of chemical compounds. These test systems were further optimized to result in better handling, reliability and sensitivity. Concerning the Vibrio fischeri test, media components such as yeast extract and bivalent cation concentrations like Ca2+ and Mg2+ were optimized. The cultivation, storage conditions and reactivation process of the stored bacteria were also improved, which enabled simpler handling and led to good reproducibility. Additionally, the respiration inhibition test with a prolonged incubation time was further analyzed using different chlorinated phenols as reference compounds. It could be stated that a longer incubation period significantly improved the sensitivity of the test system.
Subject
Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献