Affiliation:
1. Chair of Dates Industry and Technology, Department of Agricultural Engineering, College of Food and Agricultural Sciences, King Saud University, P.O. Box 2460, Riyadh 11451, Saudi Arabia
2. Agricultural Engineering Research Institute, Agriculture Research Center, Giza 12618, Egypt
3. Food Science and Nutrition Department, College of Food and Agricultural Sciences, King Saud University, P.O. Box 2460, Riyadh 11451, Saudi Arabia
4. Food Science and Nutrition Department, Faculty of Home Economics, Helwan University, P.O. Box 11611, Cairo 4034572, Egypt
5. Department of Agricultural Engineering, College of Food and Agricultural Sciences, King Saud University, Riyadh 11451, Saudi Arabia
Abstract
Milk beverage with added natural sweetener is well appreciated by consumers as a nutritious and healthy product with unique sensorial quality attributes. However, this product requires a suitable pasteurization method without significant impact on the sensorial and physicochemical quality characteristics of the product. This study optimizes the pulsed electric filed (PEF) conditions for the pasteurization of a milk-date beverage with conserved physicochemical quality properties. The effect of process variables, such as pulse off time (20, 30, and 40 μs), number of pulses (20, 50, and 80), powder ratio (10, 15, 20, and 25% w/w), storage time (2, 4, and 6 days), and storage temperature (5, 15, and 25 °C) on the responses of total viable count (TVC), color difference (∆E), pH, and total soluble solids (TSS) was evaluated using the RSM central composite design (CCD). Pulse off time, number of pulses, date powder/milk ratio (w/w), storage time, and storage temperature greatly impacted the microbial and physical properties of the beverage. The optimal conditions for decreasing the microbiological load and physical change of beverages were a pulse off time of 40 μs, number of pulses of 80, and storage temperature of 5 °C for all powder ratios. These variables gave a safe beverage for up to six days. At optimal conditions, the values of pH, TSS, ∆E, and TVC were 7.51, 15.44 °Brix, 18.01, and 0.138 Log 10 CFU/mL, respectively, for the powder ratio of 10% (w/w); 7.66, 18.6 °Brix, 21.46, and 0.284 Log 10 CFU/mL, respectively, for the powder ratio of 15% (w/w); 7.56, 21.52 °Brix, 25.24, and 0.577 Log 10 CFU/mL, respectively, for the powder ratio of 20% (w/w); and 7.2, 24.2 °Brix, 29.34, and 0.741 Log 10 CFU/mL, respectively, for the powder ratio of 25% (w/w).
Funder
King Abdulazizi City for Science and Technology (KACST), Saudi Arabia
Subject
Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering