Validity of the Maximal Heart Rate Prediction Models among Runners and Cyclists

Author:

Kasiak Przemysław Seweryn1ORCID,Wiecha Szczepan2,Cieśliński Igor2,Takken Tim3,Lach Jacek1,Lewandowski Marcin4,Barylski Marcin5,Mamcarz Artur1ORCID,Śliż Daniel1ORCID

Affiliation:

1. 3rd Department of Internal Medicine and Cardiology, Medical University of Warsaw, 04-749 Warsaw, Poland

2. Department of Physical Education and Health, Faculty in Biala Podlaska, Jozef Pilsudski University of Physical Education in Warsaw, 21-500 Biala Podlaska, Poland

3. Department of Medical Physiology, Child Development & Exercise Center, Wilhelmina Children’s Hospital, UMC Utrecht, 3584 EA Utrecht, The Netherlands

4. Department of Pharmacology and Clinical Pharmacology Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, 01-938 Warsaw, Poland

5. Department of Internal Medicine and Cardiac Rehabilitation, Medical University of Lodz, 90-549 Łódź, Poland

Abstract

Maximal heart rate (HRmax) is a widely used measure of cardiorespiratory fitness. Prediction of HRmax is an alternative to cardiopulmonary exercise testing (CPET), but its accuracy among endurance athletes (EA) requires evaluation. This study aimed to externally validate HRmax prediction models in the EA independently for running and cycling CPET. A total of 4043 runners (age = 33.6 (8.1) years; 83.5% males; BMI = 23.7 (2.5) kg·m−2) and 1026 cyclists (age = 36.9 (9.0) years; 89.7% males; BMI = 24.0 (2.7) kg·m−2) underwent maximum CPET. Student t-test, mean absolute percentage error (MAPE), and root mean square error (RMSE) were applied to validate eight running and five cycling HRmax equations externally. HRmax was 184.6 (9.8) beats·min−1 and 182.7 (10.3) beats·min−1, respectively, for running and cycling, p = 0.001. Measured and predicted HRmax differed significantly (p = 0.001) for 9 of 13 (69.2%) models. HRmax was overestimated by eight (61.5%) and underestimated by five (38.5%) formulae. Overestimated HRmax amounted to 4.9 beats·min−1 and underestimated HRmax was in the range up to 4.9 beats·min−1. RMSE was 9.1–10.5. MAPE ranged to 4.7%. Prediction models allow for limited precision of HRmax estimation and present inaccuracies. HRmax was more often underestimated than overestimated. Predicted HRmax can be implemented for EA as a supplemental method, but CPET is the preferable method.

Publisher

MDPI AG

Subject

General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3