Abstract
This article discusses issues regarding electromagnetic interference generated unintentionally by transport telematics systems and electronic security systems (ESS) located within a railway area. These systems should operate correctly, since they ensure the safety of both vehicles and passengers. The electronic devices they use are exposed to electromagnetic interference that may lead to incorrect ESS functioning. In order to determine the impact of electromagnetic interference on ESS, the authors measured unintentional low-frequency electromagnetic field generated by MV—15 and 30 kV—power lines. This enabled determining the areas with maximum values of electromagnetic interference. The next stage of the research was to develop an ESS operating process model that takes into account the impact of unintentionally generated electromagnetic interference on the operating process. Introducing the electromagnetic interference impact coefficient enables a rational selection of solutions aimed at protecting against electromagnetic interference through the application of technical and organizational measures.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)