Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments

Author:

Târtea Daniel Adrian1,Ionescu Mihaela2,Manolea Horia Octavian3,Mercuț Veronica4,Obădan Eugenia3,Amărăscu Marina Olimpia5,Mărășescu Petre Costin6,Dăguci Luminița4,Popescu Sanda Mihaela1ORCID

Affiliation:

1. Department of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

2. Department of Medical Informatics and Biostatistics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

3. Department of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

4. Department of Dental Prosthetics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

5. Department of Dental Morphology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

6. Department of Dental Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Abstract

The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann–Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = −2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.

Funder

University of Medicine and Pharmacy of Craiova

Publisher

MDPI AG

Subject

General Medicine

Reference28 articles.

1. CAD-CAM the future of digital dentistry: A review;Jain;Ann. Prosthodont. Restor. Dent.,2016

2. CAD/CAM Technology Challenges in Prosthodontics;Naji;Int. J. Dent. Res. Rev.,2021

3. CAD/CAM in prosthodontics: A gate to the future;Hussein;Int. J. Appl. Dent. Sci.,2019

4. Long term clinical performance of 10 871 dental implants with up to 22 years of follow-up: A cohort study in 4247 patients;French;Clin. Implant. Dent. Relat. Res.,2021

5. CAD/CAM Abutments versus Stock Abutments: An Update Review;Gallo;Prosthesis,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3