Green Automated Solid Phase Extraction to Measure Levofloxacin in Human Serum via Liquid Chromatography with Fluorescence Detection for Pharmacokinetic Study

Author:

Ebrahim Hager1ORCID,Sonbol Heba1,Malak Monika1,Ali Ahmed23,Aboulella Yasmine23,Hadad Ghada4,Zarad Walaa1,Emara Samy1ORCID,Bazan Lamyaa5

Affiliation:

1. Pharmaceutical Chemistry Department, Faculty of Pharmacy, Misr International University, Km 28 Ismailia Road, Cairo 44971, Egypt

2. Research Center, Misr International University, Km 28 Ismailia Road, Cairo 44971, Egypt

3. Division of Systems Biomedicine and Pharmacology, Leiden Academic Centre for Drug Research (LACDR), Leiden University, 2333 CC Leiden, The Netherlands

4. Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Suez Canal University, Ismailia 41522, Egypt

5. Pharmaceutics Department, Faculty of Pharmacy, Misr International University, Km 28 Ismailia Road, Cairo 44971, Egypt

Abstract

A simple, selective, rapid, sensitive and less costly green automated solid phase extraction bio-analytical high-performance liquid chromatographic-based technique with fluorescence detection (Aut-SPE-BA-HPLC-FL) for the quantification of levofloxacin in human serum samples has been developed and validated. The serum samples were loaded into the chromatographic system without prior treatment and then injected into short (20 mm × 4.6 mm, 20 µm) protein-coated (PC) µBondapak CN (µBCN) silica pre-column (PC-µBCN-pre-column). Levofloxacin was retained and pre-concentrated on the head of the PC-µBCN-pre-column, while proteins and other polar components were eliminated using phosphate buffer saline (PBS), pH 7.4, as the first mobile phase in the extraction step. Levofloxacin is then transferred to the analytical column; ZORBAX Eclipse XDB-C18 (150 mm × 46 mm, 5 µm), through the aid of a column-switching valve technique, on-throughs the elution mode using the second mobile phase containing a methanol and phosphate buffer (0.05 M, pH 5) in a ratio of 70:30 (v/v). Levofloxacin signals were detected using a fluorescence detector operated at excitation/emission wavelengths of 295/500 nm. The proposed Aut-SPE-BA-HPLC-FL methodology showed linearity over a levofloxacin concentration range of 10–10,000 ng/mL (r2 = 0.9992), with good recoveries ranging from 87.12 to 97.55%. Because of the validation qualities in terms of linearity, recovery, precision, accuracy, selectivity and robustness, the Aut-SPE-BA-HPLC-FL method has been used in some clinical trials for therapeutic drug monitoring and the pharmacokinetic study of levofloxacin in human serum.

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

Reference45 articles.

1. UV partial least-squares calibration and liquid chromatographic methods for direct quantitation of levofloxacin in urine;Emara;J. AOAC Int.,2007

2. An HPLC method for levofloxacin determination and its application in biomedical analysis;Czyrskia;J. Anal. Chem.,2016

3. Determination of the newer quinolones levofloxacin and moxifloxacin in plasma by high-performance liquid chromatography with fluorescence detection;Schulte;J. Chromatogr. Sci.,2006

4. Determination of levofloxacin in human serum using liquid chromatography tandem mass spectrometry;Ghimire;J. Appl. Bioanal.,2018

5. Utility of ion-pair chromatography for analysis of some anthracyclines in plasma and urine;Emara;J. Liq. Chromatogr. Relat. Technol.,1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3