Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study

Author:

Vinci R.,Manacorda M.,Abundo R.,Lucchina A.G.,Scarano A.ORCID,Crocetta C.ORCID,Lo Muzio L.ORCID,Gherlone E.F.,Mastrangelo F.

Abstract

Purpose: To evaluate the accuracy of computer-aided dental implant positions obtained with mucosal-supported templates as compared to Three-Dimensional (3D) planning. Materials and methods: One-hundred implants were inserted into 14 edentulous patients using the All-on-4/6 protocol after surgical virtual planning with RealGUIDE, 3DIEMME, and Geomagic software. After 6 months, three-dimensional neck (V) and apex (S) spatial coordinates of implants and angle inclination displacements as compared to virtual plans were evaluated. Results: The S maxilla coordinates revealed a significant discrepancy between clinical and virtual implant positions (p-value = 0.091). The V coordinates showed no significant differences (p-value = 0.71). The S (p-value = 0.017) and V (p-value = 0.038) mandible coordinates showed significant discrepancies between the clinical and virtual positions of the screws. Implant evaluation showed a 1-mm in average of the horizontal deviation in the V point and a 1.6-mm deviation in the S point. A mean 5° angular global deviation was detected. The multivariate permutation test of the S (p-value = 0.02) confirmed the difference. Greater errors in the mandible were detected as compared to the maxilla, and a higher S discrepancy was found in the posterior jaw compared to the anterior section of both the mandible and maxilla. Conclusions: Computer-aided surgery with mucosal-supported templates is a predictable procedure for implant placement. Data showed a discrepancy between the actual dental implant position as compared to the virtual plan, but this was not statistically significant. However, the horizontal and angle deviations detected indicated that flap surgery should be used to prevent implant positioning errors due to poor sensitivity and accuracy in cases of severe jaw atrophy.

Publisher

MDPI AG

Subject

General Medicine

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Two-stream regression network for dental implant position prediction;Expert Systems with Applications;2024-01

2. TCSloT: Text Guided 3D Context and Slope Aware Triple Network for Dental Implant Position Prediction;2023 IEEE International Conference on Bioinformatics and Biomedicine (BIBM);2023-12-05

3. A prediction method and evaluation for assessing guide-supported dental implant accuracy;Computer Methods in Biomechanics and Biomedical Engineering;2023-11-20

4. A novel mixed reality-guided dental implant placement navigation system based on virtual-actual registration;Computers in Biology and Medicine;2023-11

5. A systematic review of the accuracy of digital surgical guides for dental implantation;International Journal of Implant Dentistry;2023-10-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3