Abstract
Based on traditional sandwich structure, two piezoelectric transducers were designed to meet the strict underwater application backgrounds such as high pressure, corrosion resistance, and high strength. Both transducers integrated most of previous researches while one transducer has a multilayer cavity structure which is different from the other structure and previous transducer structures. After a detailed simulation analysis of every structural parameter, key parameters were pointed out to have an obvious influence on its performance. Then, two models were constructed and compared with chosen sets of geometry parameters and manufacturing process, which can also provide a reference for low-frequency transducer design. The simulation results and experimental results of our transducers show a good consistency which indicates the cavity structure can reduce the resonance frequency.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry