Image-Free Ultrasound Blood-Flow Monitoring Circuit System with Automatic Range-Gate Positioning Scheme: A Pilot Study

Author:

Park Hyun-Tae,Um Ji-Yong

Abstract

This work proposes a proof-of-concept ultrasound blood-flow-monitoring circuit system using a single-element transducer. The circuit system consists of a single-element ultrasonic transducer, an analog interface circuit, and a field-programmable gate array (FPGA). Since the system uses a single-element transducer, an ultrasound image cannot be reconstructed unless scanning with mechanical movement is used. An ultrasound blood-flow monitor basically needs to acquire a Doppler sample volume by positioning a range gate at a vessel region on a scanline. Most recent single-transducer-based ultrasound pulsed-wave Doppler devices rely on a manual adjustment of the range gate to acquire Doppler sample volumes. However, the manual adjustment of the range gate depends on the user’s experience, and it can be time consuming if a transducer is not properly positioned. Thus, automatic range-gate-positioning is more desirable for image-free pulsed-wave Doppler devices. This work proposes a circuit system which includes a new automatic range-gate-positioning scheme. It blindly tracks the position of a blood vessel on a scanline by using the accumulation of Doppler amplitude deviations and a hysteresis slicing function. The proposed range-gate-positioning scheme has been implemented in an FPGA for real-time operation and is based on addition-only computations, except for filter parts to reduce the complexity of computation in the hardware. The proposed blood-flow-monitoring circuit system has been implemented with discrete commercial chips for proof-of-concept purposes. It uses a center frequency of 2 MHz and a system-clock frequency of 20 MHz. The FPGA only utilizes 5.6% of slice look-up-tables (LUTs) for implementation of the range-gate-positioning scheme. For measurements, the circuit system was utilized to interrogate a customized flow phantom model, which included two vessel-mimicking channels. The circuit system successfully acquired Doppler sample volumes by positioning a range gate on a fluid channel. In addition, the estimated Doppler shift frequency shows a good agreement with the theoretical value.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3