Abstract
The presented procedure combines experience from two LC-MS/MS methods previously developed by our team for NSAIDs determination in meat and milk. The novelty was a modification of sample preparation and combining LC-MS/MS method for milk and muscle. The clean-up procedure was investigated, leading to a change from SPE to dSPE with C18 bulk sorbent. Unlike most of the existing methods, chromatographic separation was achieved on a C8 chromatographic column. This method was developed and validated under European Commission Decision 2002/657/EC. Recovery for milk samples values between 86.3% to 108%, with the coefficient of variation, varied from 5.51% to 16.2%. The recovery for muscle was calculated to be between 85.0% and 109%, and the coefficient of variation was—4.73% to 16.6%. The validation results prove that the method is suitable for confirmatory purposes in milk and muscle. Of 452 samples tested in 2019 and 2020, two have been identified as non-compliant.
Subject
Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献