Computation of Vascular Parameters: Implementing Methodology and Performance Analysis

Author:

Sikkandar Mohamed Yacin1ORCID,Padmanabhan Sridharan2,Mohan Bobby2ORCID,AlMohimeed Ibrahim1,Alassaf Ahmad1,Alshewaier Shady A.3ORCID,Almukil Ali Abdullah1,Begum Sabarunisha4

Affiliation:

1. Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah 11952, Saudi Arabia

2. Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai 602105, India

3. Department of Physical Therapy, College of Applied Medical Sciences, Majmaah University, Al Majmaah 11952, Saudi Arabia

4. Department of Biotechnology, P.S.R. Engineering College, Sivakasi 626140, India

Abstract

This paper presents the feasibility of automated and accurate in vivo measurements of vascular parameters using an ultrasound sensor. The continuous and non-invasive monitoring of certain parameters, such as pulse wave velocity (PWV), blood pressure (BP), arterial compliance (AC), and stiffness index (SI), is crucial for assessing cardiovascular disorders during surgeries and follow-up procedures. Traditional methods, including cuff-based or invasive catheter techniques, serve as the gold standard for measuring BP, which is then manually used to calculate AC and SI through imaging algorithms. In this context, the Continuous and Non-Invasive Vascular Stiffness and Arterial Compliance Screener (CaNVAS) is developed to provide continuous and non-invasive measurements of these parameters using an ultrasound sensor. By driving 5 MHz (ranging from 2.2 to 10 MHz) acoustic waves through the arterial walls, capturing the reflected echoes, and employing pre-processing techniques, the frequency shift is utilized to calculate PWV. It is observed that PWV measured by CaNVAS correlates exponentially with BP values obtained from the sphygmomanometer (BPMR-120), enabling the computation of instantaneous BP values. The proposed device is validated through measurements conducted on 250 subjects under pre- and post-exercise conditions, demonstrating an accuracy of 95% and an average coefficient of variation of 12.5%. This validates the reliability and precision of CaNVAS in assessing vascular parameters.

Funder

Majmaah University

Publisher

MDPI AG

Subject

Clinical Biochemistry,General Medicine,Analytical Chemistry,Biotechnology,Instrumentation,Biomedical Engineering,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3