ECG Localization Method Based on Volume Conductor Model and Kalman Filtering

Author:

Nakano Yuki,Rashed Essam A.ORCID,Nakane Tatsuhito,Laakso Ilkka,Hirata AkimasaORCID

Abstract

The 12-lead electrocardiogram was invented more than 100 years ago and is still used as an essential tool in the early detection of heart disease. By estimating the time-varying source of the electrical activity from the potential changes, several types of heart disease can be noninvasively identified. However, most previous studies are based on signal processing, and thus an approach that includes physics modeling would be helpful for source localization problems. This study proposes a localization method for cardiac sources by combining an electrical analysis with a volume conductor model of the human body as a forward problem and a sparse reconstruction method as an inverse problem. Our formulation estimates not only the current source location but also the current direction. For a 12-lead electrocardiogram system, a sensitivity analysis of the localization to cardiac volume, tilted angle, and model inhomogeneity was evaluated. Finally, the estimated source location is corrected by Kalman filter, considering the estimated electrocardiogram source as time-sequence data. For a high signal-to-noise ratio (greater than 20 dB), the dominant error sources were the model inhomogeneity, which is mainly attributable to the high conductivity of the blood in the heart. The average localization error of the electric dipole sources in the heart was 12.6 mm, which is comparable to that in previous studies, where a less detailed anatomical structure was considered. A time-series source localization with Kalman filtering indicated that source mislocalization could be compensated, suggesting the effectiveness of the source estimation using the current direction and location simultaneously. For the electrocardiogram R-wave, the mean distance error was reduced to less than 7.3 mm using the proposed method. Considering the physical properties of the human body with Kalman filtering enables highly accurate estimation of the cardiac electric signal source location and direction. This proposal is also applicable to electrode configuration, such as ECG sensing systems.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3