Improvement of Quantitative Single-Photon Emission Computed Tomography Image Quality by the New Step-and-Shoot Scan Mode

Author:

Yamamoto Hiroki,Sasaki Ami,Osaka Mizuki,Shirakawa Koji,Seino Morio,Matsuhashi Takaaki,Takahashi Yasuyuki,Zeniya TsutomuORCID,Hosokawa Shota,Narita Masataka,Aoki Masahiko

Abstract

The step-and-shoot (SS) mode and continuous mode are currently used for single-photon emission computed tomography (SPECT) scan mode, and a new scan mode that combines both modes, step-and-shoot plus continuous (SSC) mode, was developed. It is expected to allow a shorter scan time and lower injected dose because the SSC mode is more sensitive than the SS mode. We confirmed the image quality of this scan mode, including various quantitative correction methods for scatter (SC), attenuation (AC), and resolution recovery (RR) in a phantom study and clinical case study. Image quality was evaluated by the count, contrast-to-noise ratio (CNR), and percent of the coefficient of variation (%CV). Independent of the correction methods, the count, CNR, and %CV of the SSC mode were superior to those of the SS mode. The ACSCRR was the best method, with a maximum increased rate of 66.4% in counts and 57.8% in CNR for the 13-mm sphere and 19.6% in CNR for other sphere sizes. The %CV for the SSC mode was the best for AC and ACRR, which was at 15.1%. With regards to attaining short bone SPECT scan time, the combination of the SSC mode and ACRR or ACSCRR demonstrated the best physical performance.

Publisher

MDPI AG

Subject

Automotive Engineering

Reference13 articles.

1. Diagnosis of bone metastases: a meta-analysis comparing 18FDG PET, CT, MRI and bone scintigraphy

2. Point of acquisition, processing, display and output for standardized images with clinical usefulness;Masuda;Jpn. J. Nucl. Med. Technol.,2008

3. Clinical evaluation of General Electric new Swiftscan solution in bone scintigraphy on NaI-camera: A head to head comparison with Siemens Symbia

4. The usefulness of SwiftScan technology for bone scintigraphy using a novel anthropomorphic phantom

5. Guidelines of standardization of bone SPECT imaging;Jpn. J. Nucl. Med. Technol.,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3