Author:
Shibutani Takayuki,Onoguchi Masahisa,Naoi Yuka,Yoneyama Hiroto,Konishi Takahiro,Tatami Ringo,Nakajima Kenichi
Abstract
AbstractThe aim of this study was to demonstrate the usefulness of SwiftScan with a low-energy high-resolution and sensitivity (LEHRS) collimator for bone scintigraphy using a novel bone phantom simulating the human body. SwiftScan planar image of lateral view was acquired in clinical condition; thereafter, each planar image of different blend ratio (0–80%) of Crality 2D processing were created. SwiftScan planar images with reduced acquisition time by 25–75% were created by Poisson’s resampling processing. SwiftScan single photon emission computed tomography (SPECT) was acquired with step-and-shoot and continuous mode, and SPECT images were reconstructed using a three-dimensional ordered subset expectation maximization incorporating attenuation, scatter and spatial resolution corrections. SwiftScan planar image showed a high contrast to noise ratio (CNR) and low percent of the coefficient of variance (%CV) compared with conventional planar image. The CNR of the tumor parts in SwiftScan SPECT was higher than that of the conventional SPECT image of step and shoot acquisition, while the %CV showed the lowest value in all systems. In conclusion, SwiftScan planar and SPECT images were able to reduce the image noise compared with planar and SPECT image with a low-energy high-resolution collimator, so that SwiftScan planar and SPECT images could be obtained a high CNR. Furthermore, the SwiftScan planar image was able to reduce the acquisition time by 25% when the blend ratio of Clarity 2D processing set to more than 40%.
Publisher
Springer Science and Business Media LLC
Reference29 articles.
1. Donohoe, K. J. et al. Procedure guideline for bone scintigraphy: 1.0. Society of Nuclear Medicine. J. Nucl. Med. 37, 1903–1906 (1996).
2. Van den Wyngaert, T. et al. The EANM practice guidelines for bone scintigraphy. Eur. J. Nucl. Med. Mol. Imaging 43, 1723–1738. https://doi.org/10.1007/s00259-016-3415-4 (2016).
3. Bartel, T. B. et al. SNMMI procedure standard for bone scintigraphy 4.0. J. Nucl. Med. Technol. 46, 398–404 (2018).
4. Han, L. J. et al. Comparison of bone single-photon emission tomography and planar imaging in the detection of vertebral metastases in patients with back pain. Eur. J. Nucl. Med. 25, 635–638. https://doi.org/10.1007/s002590050266 (1998).
5. Horger, M. et al. Evaluation of combined transmission and emission tomography for classification of skeletal lesions. AJR Am. J. Roentgenol. 183, 655–661. https://doi.org/10.2214/ajr.183.3.1830655 (2004).
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献