How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA–GTA Fricke Gel Dosimeters: A Spectrophotometric Study

Author:

Scotti Martina,Arosio PaoloORCID,Brambilla ElisaORCID,Gallo SalvatoreORCID,Lenardi CristinaORCID,Locarno SilviaORCID,Orsini FrancescoORCID,Pignoli Emanuele,Pedicone Luca,Veronese IvanORCID

Abstract

The development of Fricke gel (FG) dosimeters based on poly(vinyl alcohol) (PVA) as the gelling agent and glutaraldehyde (GTA) as the cross-linker has enabled significant improvements in the dose response and the stability over time of spatial radiation dose distributions. However, a standard procedure for preparing FG in terms of reagent concentrations is still missing in the literature. This study aims to investigate, by means of spectrophotometric analyses, how the sensitivity to the radiation dose and the range of linearity of the dose–response curve of PVA-GTA-FG dosimeters loaded with xylenol orange sodium salt (XO) are influenced by ferrous ammonium sulphate (FAS) and XO concentrations. Moreover, the effect of different concentrations of such compounds on self-oxidation phenomena in the dosimeters was evaluated. PVA-GTA-FG dosimeters were prepared using XO concentrations in the range 0.04–0.80 mM and FAS in the range 0.05–5.00 mM. The optical absorbance properties and the dose response of FG were investigated in the interval 0.0–42.0 Gy. The results demonstrate that the amount of FAS and XO determines both the sensitivity to the absorbed dose and the interval of linearity of the dose–response curve. The study suggests that the best performances of FG dosimeters for spectrophotometric analyses can be obtained using 1.00–0.40 mM and 0.200–0.166 mM concentrations of FAS and XO, respectively.

Publisher

MDPI AG

Subject

Polymers and Plastics,Organic Chemistry,Biomaterials,Bioengineering

Reference64 articles.

1. The chemical action of roentgen rays on diluted ferrous sulphate solutions as a measure of dose;Fricke;Am. J. Roentgenol.,1927

2. Primary Radiation Standards;Andreo,2017

3. Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry

4. A review study on application of gel dosimeters in low energy radiation dosimetry;Zahra;Appl. Radiat. Isot.,2022

5. Determination of Iron in Solutions with the Ferric–Xylenol Orange Complex

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3