Assessment of Bacterial Contamination of Air at the Museum of King John III’s Palace at Wilanow (Warsaw, Poland): Selection of an Optimal Growth Medium for Analyzing Airborne Bacteria Diversity

Author:

Dziurzynski MikolajORCID,Ciuchcinski Karol,Dyda Magdalena,Szych Anna,Drabik Paulina,Laudy AgnieszkaORCID,Dziewit LukaszORCID

Abstract

There is no standardized protocol for the assessment of microbial air contamination in museums and other cultural heritage sites. Therefore, most museums conduct such assessments based on their own guidelines or good practices. Usually, microbial air contamination is assessed using only classical microbiology methods with the application of a single growth medium. Therefore, this medium should be carefully selected to limit any selective cultivation bias. Metabarcoding, i.e., a next-generation sequencing (NGS)-based method, combined with classical microbiological culturing was used to assess the effectiveness of various media applications in microbiological screening at the Museum of King John III’s Palace at Wilanow (Warsaw, Poland). The obtained results indicated that when using a classical microbiology approach to assess the microbial air contamination at the museum, the selection of a proper growth medium was critical. It was shown that the use of rich media (commonly applied by museum conservators) introduced significant bias by severely underreporting putative human pathogens and the bacterial species involved in biodeterioration. Therefore, we recommend the use of other media, such as Frazier or Reasoner’s 2A (R2A) medium, as they could yield more diverse communities and recovered the highest number of genera containing human pathogens, which may be suitable for public health assessments.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference59 articles.

1. Airborne Contagion and Air Hygiene. An Ecological Study of Droplet Infections;Wells,1955

2. Biohazards in the Indoor Environment—A Role for Threshold Limit Values in Exposure Assessment;Górny,2011

3. Risk factors for particulate and microbial contamination of air in operating theatres

4. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres

5. Microbiological Quality of Indoor Air in University Libraries

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3