From Personalized to Precision Medicine in Oncology: A Model-Based Dosing Approach to Optimize Achievement of Imatinib Target Exposure

Author:

Goutelle Sylvain123ORCID,Guidi Monia456,Gotta Verena7,Csajka Chantal568ORCID,Buclin Thierry4ORCID,Widmer Nicolas469ORCID

Affiliation:

1. Service de Pharmacie, GH Nord, Hospices Civils de Lyon, 69002 Lyon, France

2. Univ. Lyon, Université Claude Bernard Lyon 1, UMR CNRS 5558, LBBE—Laboratoire de Biométrie et Biologie Évolutive, 69100 Villeurbanne, France

3. Univ. Lyon, Université Claude Bernard Lyon 1, ISPB—Faculté de Pharmacie de Lyon, 69008 Lyon, France

4. Service of Clinical Pharmacology, Lausanne University Hospital and University of Lausanne, 1011 Lausanne, Switzerland

5. Center for Research and Innovation in Clinical Pharmaceutical Sciences, University Hospital and University of Lausanne, 1011 Lausanne, Switzerland

6. Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva and University of Lausanne, 1211 Geneva, Switzerland

7. Pediatric Pharmacology and Pharmacometrics, University of Basel Children’s Hospital, 4056 Basel, Switzerland

8. School of Pharmaceutical Sciences, University of Geneva, 1205 Geneva, Switzerland

9. Pharmacy of the Eastern Vaud Hospitals, 1847 Rennaz, Switzerland

Abstract

Imatinib is a targeted cancer therapy that has significantly improved the care of patients with chronic myeloid leukemia (CML) and gastrointestinal stromal tumor (GIST). However, it has been shown that the recommended dosages of imatinib are associated with trough plasma concentration (Cmin) lower than the target value in many patients. The aims of this study were to design a novel model-based dosing approach for imatinib and to compare the performance of this method with that of other dosing methods. Three target interval dosing (TID) methods were developed based on a previously published PK model to optimize the achievement of a target Cmin interval or minimize underexposure. We compared the performance of those methods to that of traditional model-based target concentration dosing (TCD) as well as fixed-dose regimen using simulated patients (n = 800) as well as real patients’ data (n = 85). Both TID and TCD model-based approaches were effective with about 65% of Cmin achieving the target imatinib Cmin interval of 1000–2000 ng/mL in 800 simulated patients and more than 75% using real data. The TID approach could also minimize underexposure. The standard 400 mg/24 h dosage of imatinib was associated with only 29% and 16.5% of target attainment in simulated and real conditions, respectively. Some other fixed-dose regimens performed better but could not minimize over- or underexposure. Model-based, goal-oriented methods can improve initial dosing of imatinib. Combined with subsequent TDM, these approaches are a rational basis for precision dosing of imatinib and other drugs with exposure–response relationships in oncology.

Publisher

MDPI AG

Subject

Pharmaceutical Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3