Magnetic contacts are one of the basic components of an alarm system, providing access to buildings, especially windows and doors. From long-term reliability tests, it can be concluded that magnetic contacts show sufficient reliability. Due to global warming, we can measure high as well as low ambient temperatures in the vicinity of magnetic contacts, which can directly affect their reliability. As part of partial tests, research into the reliability of magnetic contacts, we created a test device with which their reaction distance was examined under extreme conditions simulated in a thermal chamber. The results of the practical tests have yielded surprising results.