Trace minerals play an essential role in methane production via anaerobic digestion (AD). It is important to monitor Ni(II) and Co(II) concentrations and the Ni/Co concentration ratio for the rapid diagnosis of the ecological status or activity of methanogens in AD. Electrochemical detection of Ni(II) and Co(II) was investigated by coating the Bi-chitosan nanocomposite on a glassy carbon electrode (GCE) via the electrodeposition technique. A square-wave adsorptive cathodic stripping voltammetry technique (SWAdCSV) was applied and optimized when dimethylglyoxime (DMG) was used as the chelating agent for Ni(II) and Co(II) measurements. The SWAdCSV results showed that the current peaks for Co(II) detection are 6.1 times greater than the current peaks for Ni(II) measurements, probably due to the different affinity of DMG molecules between Ni(II) and Co(II). DMG molecules demonstrated higher selectivity toward Co(II) cations compared to Ni(II). The modified Bi-chitosan GCE developed in this study showed a relatively wide range of the Ni(II) and Co(II) concentrations (2–100 µg L−1) with a limit of detection of 3.6 µg L−1 for Ni(II) and 2.4 µg L−1 for Co(II), respectively. The developed sensor was applied to Ni(II) and Co(II) spiked natural water samples and showed good performance of detection with 12 consecutive measurements. Overall, the fabricated sensor showed excellent sensitivity toward Ni(II) and Co(II) in natural water samples.