Abstract
In the present study, a relatively novel non-destructive testing (NDT) method called the coplanar capacitive sensing technique was applied in order to detect different sizes of rebars in a reinforced concrete (RC) structure. This technique effectively detects changes in the dielectric properties during scanning in various sections of concrete with and without rebars. Numerical simulations were carried out by three-dimensional (3D) finite element modelling (FEM) in COMSOL Multiphysics software to analyse the impact of the presence of rebars on the electric field generated by the coplanar capacitive probe. In addition, the effect of the presence of a surface defect on the rebar embedded in the concrete slab was demonstrated by the same software for the first time. Experiments were performed on a concrete slab containing rebars, and were compared with FEM results. The results showed that there is a good qualitative agreement between the numerical simulations and experimental results.
Funder
Natural Sciences and Engineering Research Council
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献