The Computational Fluid Dynamics (CFD) Analysis of the Pressure Sensor Used in Pulse-Operated Low-Pressure Gas-Phase Solenoid Valve Measurements

Author:

Szpica DariuszORCID,Mieczkowski GrzegorzORCID,Borawski AndrzejORCID,Leisis VitalisORCID,Diliunas SauliusORCID,Pilkaite Tilmute

Abstract

This paper presents a flow analysis of the original pressure sensor used to determine times until full opening and closing of the pulse-operated low-pressure gas-phase solenoid valve. The sensor in question, due to the fast variation of the process lasting several milliseconds, has high requirements in terms of response time and ability to identify characteristic parameters. A CFD code has been employed to successfully model the flow behavior of the original pressure sensor used to determine times until full opening and closing of the pulse-operated low-pressure gas-phase solenoid valve at different inlet flow conditions, using the Eulerian multiphase model, established on the Euler–Euler approach, implemented in the commercial CFD package ANSYS Fluent. The results of the modelling were validated against the experimental data and also give more comprehensive information on the flow, such as the plunger displacement waveform. The flow calculations were dynamic in nature; therefore, the experimental plunger displacement waveforms were entered as input in the software for dynamic mash implementation. In identifying the times until full opening and closing, the characteristic points of the pressure waveform on the pressure sensor plate were adopted. CFD flow calculations confirmed the accuracy of identifying the times until full opening and closing by relating them to the results from the plunger displacement sensor. The validation of the results of calculations with the analyzed sensor and the original stand also confirmed the correctness of the use of this type of method for the assessment of gas injector operating times. In the case of time until full opening, the CFD calculations were shown to be consistent with experimental tests, with only a few cases where the relative difference with respect to the displacement sensor reached 3%. The situation was slightly worse in the case of time until full closing, where the results of CFD calculations were in agreement with the displacement sensor, while the experimental test stands had a relative difference of up to 21%. It should be remembered that the sensor evaluates times below 5 × 10−3 s, and its construction and response time determine the use depending on the adopted level of accuracy.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3