Impact of Anterior Malposition and Bone Cement Augmentation on the Fixation Strength of Cephalic Intramedullary Nail Head Elements

Author:

Pastor TorstenORCID,Zderic IvanORCID,Schopper Clemens,Haefeli Pascal C.,Kastner PhilippORCID,Souleiman FirasORCID,Gueorguiev BoykoORCID,Knobe MatthiasORCID

Abstract

Background and Objectives: Intramedullary nailing of trochanteric fractures can be challenging and sometimes the clinical situation does not allow perfect implant positioning. The aim of this study was (1) to compare in human cadaveric femoral heads the biomechanical competence of two recently launched cephalic implants inserted in either an ideal (centre–centre) or less-ideal anterior off-centre position, and (2) to investigate the effect of bone cement augmentation on their fixation strength in the less-ideal position. Materials and Methods: Fourty-two paired human cadaveric femoral heads were assigned for pairwise implantation using either a TFNA helical blade or a TFNA screw as head element, implanted in either centre–centre or 7 mm anterior off-centre position. Next, seven paired specimens implanted in the off-centre position were augmented with bone cement. As a result, six study groups were created as follows: group 1 with a centre–centre positioned helical blade, paired with group 2 featuring a centre–centre screw, group 3 with an off-centre positioned helical blade, paired with group 4 featuring an off-centre screw, and group 5 with an off-centre positioned augmented helical blade, paired with group 6 featuring an off-centre augmented screw. All specimens were tested until failure under progressively increasing cyclic loading. Results: Stiffness was not significantly different among the study groups (p = 0.388). Varus deformation was significantly higher in group 4 versus group 6 (p = 0.026). Femoral head rotation was significantly higher in group 4 versus group 3 (p = 0.034), significantly lower in group 2 versus group 4 (p = 0.005), and significantly higher in group 4 versus group 6 (p = 0.007). Cycles to clinically relevant failure were 14,919 ± 4763 in group 1, 10,824 ± 5396 in group 2, 10,900 ± 3285 in group 3, 1382 ± 2701 in group 4, 25,811 ± 19,107 in group 5 and 17,817 ± 11,924 in group 6. Significantly higher number of cycles to failure were indicated for group 1 versus group 2 (p = 0.021), group 3 versus group 4 (p = 0.007), and in group 6 versus group 4 (p = 0.010). Conclusions: From a biomechanical perspective, proper centre–centre implant positioning in the femoral head is of utmost importance. In cases when this is not achievable in a clinical setting, a helical blade is more forgiving in the less ideal (anterior) malposition when compared to a screw, the latter revealing unacceptable low resistance to femoral head rotation and early failure. Cement augmentation of both off-centre implanted helical blade and screw head elements increases their resistance against failure; however, this effect might be redundant for helical blades and is highly unpredictable for screws.

Funder

AO Foundation

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3