Is augmented femoral lateral plating with helically shaped medial plates biomechanically advantageous over straight medial plates?

Author:

Pastor Torsten12ORCID,Zderic Ivan1ORCID,Drenchev Ludmil3,Skulev Hristo K.3,Berk Till14ORCID,Beeres Frank J. P.25,Link Björn‐Christian2,Gueorguiev Boyko1ORCID,Stoffel Karl6,Knobe Matthias27

Affiliation:

1. AO Research Institute Davos Davos Switzerland

2. Department of Orthopaedic and Trauma Surgery Lucerne Cantonal Hospital Lucerne Switzerland

3. Bulgarian Academy of Sciences Institute of Metal Science “Acad. A. Balevski” Sofia Bulgaria

4. Department of Trauma University Hospital Zurich Zurich Switzerland

5. Department of Health Science and Medicine University of Lucerne Lucerne Switzerland

6. Department of Orthopaedics and Traumatology University Hospital Basel Basel Switzerland

7. Medical Faculty, RWTH Aachen University Hospital Aachen Germany

Abstract

AbstractDual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP‐DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15‐hole LCP‐DF. Following, they were pairwise instrumented with either an additional medial straight 14‐hole LCP (group 1) or a 90°‐helical shape LCP (group 2). All specimens were biomechanically tested under quasi‐static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3