Management of XEN Gel Stent Exposure with Conjunctival Erosion via Rotational Conjunctival Flap and Amniotic Membrane Transplantation—A Case Report

Author:

Lee Chang Kyu,Seo Je HyunORCID,Lim Su-HoORCID

Abstract

Background: Despite its proven effectiveness and safety profile, the XEN gel stent (Allergan Inc., CA, USA) for minimally invasive glaucoma surgery (MIGS) has a probability of postoperative complications, including postoperative hypotony, hyphema, stent migration, stent obstruction, bleb fibrosis, and fibrin formation. In particular, the use of adjunctive Mitomycin-C (MMC) might be associated with bleb-related complications, including conjunctival erosion, XEN gel stent exposure, and blebitis. However, there are few studies on XEN gel stent exposure and its management. We describe a case of XEN gel stent exposure with conjunctival erosion 18 months postoperatively, which resolved effectively after combination treatment with a rotational conjunctival flap and amniotic membrane transplantation. Case presentation: A 74-year-old Korean male patient with diabetes and hypertension underwent uncomplicated ab interno XEN gel stent implantation with a subconjunctival injection of 0.1 cc of 0.02% MMC and presented with low intraocular pressure (IOP) with a well-functioning filtering bleb. Periocular pain and tearing developed 18 months after the initial operation, with mild deterioration of visual acuity to 20/100. Despite conservative medical treatment, the conjunctival erosion was not relieved. Anterior segment optical coherence tomography (AS-OCT) revealed an exposed XEN gel stent with conjunctival erosion. We performed bleb revision surgery using a rotational conjunctival flap and amniotic membrane transplantation. Slit-lamp examination and AS-OCT showed a well-formed moderate bleb without leakage, and IOP continued to be well controlled (14 mm Hg with latanoprost) until six months after bleb revision. Conclusions: This case report highlights the importance of careful examination, including slit-lamp examination, the Seidel test, and AS-OCT, to identify accurate anatomical positioning and to monitor ocular surface changes after XEN gel stent implantation with MMC or 5-FU. Combination treatment (rotational conjunctival flap and amniotic membrane transplantation) may be relatively safe for persistent XEN gel stent exposure.

Funder

VHS Medical Center Research Grant, Republic of Korea

Publisher

MDPI AG

Subject

General Medicine

Reference11 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Xen gel stent implant for persistent glaucoma after silicone oil removal;European Journal of Ophthalmology;2024-08-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3