Xen gel stent implant for persistent glaucoma after silicone oil removal

Author:

Boscia Francesco1,Ferreri Paolo1,Sisto Dario1,Niro Alfredo2ORCID,Boscia Giacomo13ORCID,Scotti Giacomo1ORCID,Viggiano Pasquale1,Sborgia Alessandra1,Sborgia Giancarlo1,Giancipoli Ermete4,Alessio Giovanni1

Affiliation:

1. Eye Clinic, Department of Medical Science, Neuroscience and Sense Organs, University of Bari, 70124, Bari, Italy

2. Eye Clinic, “SS. ANNUNZIATA” Hospital, ASL TA, 74010, Taranto, Italy

3. Eye Clinic Section, Department of Surgical Sciences, University of Turin, 10122, Turin, Italy

4. Eye Clinic, Department of Medical and Surgical Sciences, University of Foggia, 71122, Foggia, Italy

Abstract

Purpose To evaluate the effectiveness and safety of the XEN-Stent for managing unresponsive to medical therapy secondary glaucoma after silicone oil (SO) removal. Methods This retrospective chart reviewed 12 patients who underwent vitrectomy and SO endotamponade. They experienced intraocular pressure (IOP) elevation after SO removal despite taking the maximum tolerated glaucoma medication. Eleven eyes underwent an XEN-implant, while 1 underwent an XEN-implant with phacoemulsification/IOL implantation. The primary outcome was to achieve success criteria: IOP <18 mmHg and >20% IOP reduction without medication (complete success) or with medication (qualified success) and without a secondary IOP-lowering procedure. IOP, best-corrected visual acuity (BCVA), and the number of glaucoma medications (Glaucoma Medication Score-GMS) were recorded at baseline, 1 day, 1 week, 1 (M1), 3 (M3), 6 (M6), and 12 (M12) months postoperatively. Results Baseline characteristics included males percentage 66.6%, mean age of 61.8 ± 5.7 years, BCVA 0.69 ± 0.3 logMAR, IOP 30 ± 4.2 mmHg, and GMS 3.1 ± 0.5. There was a significant reduction in IOP by 14 ± 1.9 mmHg and GMS by 0.27 ± 0.6 at M12 compared to baseline (p < 0.01), but no significant change in BCVA (p = 0.21). Complete success dropped to 50% (M3), rising to 75% (M6, M12) after needling. Two patients achieved qualified success at M12. Needling was performed in 6 eyes, with 3 requiring a second procedure. Ex-PRESS was required in 1 eye. One eye experienced hypotony and hyphema, which resolved within a week. Conclusion XEN implant may be an initial treatment for persistent post SO removal glaucoma with minimal complications. Needling procedures can help maintain or restore surgical success.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3