Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study

Author:

Lodde Moritz F.ORCID,Katthagen J. Christoph,Schopper Clemens O.ORCID,Zderic IvanORCID,Richards R. GeoffORCID,Gueorguiev BoykoORCID,Raschke Michael J.,Hartensuer RenéORCID

Abstract

Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical shear or transforaminal sacral fractures. The aim of this study was to compare the biomechanical performance of fixations using one (Group 1) or two (Group 2) standard SI screws versus one SI screw with bone cement augmentation (Group 3). Materials and Methods: Unstable fractures of the pelvic ring (AO/OTA 61-C1.3, FFP IIc) were simulated in 21 artificial pelvises by means of vertical osteotomies in the ipsilateral anterior and posterior pelvic ring. A supra-acetabular external fixator was applied to address the anterior fracture. All specimens were tested under progressively increasing cyclic loading until failure, with monitoring by means of motion tracking. Fracture site displacement and cycles to failure were evaluated. Results: Fracture displacement after 500 cycles was lowest in Group 3 (0.76 cm [0.30] (median [interquartile range, IQR])) followed by Group 1 (1.42 cm, [0.21]) and Group 2 (1.42 cm [1.66]), with significant differences between Groups 1 and 3, p = 0.04. Fracture displacement after 1000 cycles was significantly lower in Group 3 (1.15 cm [0.37]) compared to both Group 1 (2.19 cm [2.39]) and Group 2 (2.23 cm [3.65]), p ≤ 0.04. Cycles to failure (Group 1: 3930 ± 890 (mean ± standard deviation), Group 2: 3676 ± 348, Group 3: 3764 ± 645) did not differ significantly between the groups, p = 0.79. Conclusions: In our biomechanical setup cement augmentation of one SI screw resulted in significantly less displacement compared to the use of one or two SI screws. However, the number of cycles to failure was not significantly different between the groups. Cement augmentation of one SI screw seems to be a useful treatment option for posterior pelvic ring fixation, especially in osteoporotic bone.

Publisher

MDPI AG

Subject

General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3