Abstract
The feasibility of reverse osmosis (RO) for treating coking wastewaters from a steel manufacturing plant, rich in ammonium thiocyanate was assessed. DOW FILMTECTM SW30 membrane performance with synthetic and real thiocyanate-containing solutions was established at the laboratory and (onsite) pilot plant scale. No short-term fouling was observed, and the data followed the known solution-diffusion model and the film theory. Those models, together with non-steady state mass balances, were used in simulations that aided to design a full scale two-stage RO plant for thiocyanate separation.
Subject
Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology