Abstract

Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Validation of Automatic Cochlear Measurements Using OTOPLAN® Software;Journal of Personalized Medicine;2023-05-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3