Validation of Automatic Cochlear Measurements Using OTOPLAN® Software

Author:

Paouris Dimitrios1ORCID,Kunzo Samuel1,Goljerová Irina1

Affiliation:

1. Clinic of Pediatric Otorhinolaryngology of the Medical Faculty, National Institute of Children’s Diseases, Comenius University, 83340 Bratislava, Slovakia

Abstract

Introduction: Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic measurement method. Materials and Methods: A retrospective evaluation of pre-operative HRCT images of 109 ears (56 patients) was conducted, using a development version of the OTOPLAN® software. Inter-rater (intraclass) reliability and execution time were assessed for manual (surgeons R1 and R2) vs. automatic (AUTO) results. The analysis included A-Value (Diameter), B-Value (Width), H-Value (Height), and CDLOC-length (Cochlear Duct Length at Organ of Corti/Basilar membrane). Results: The measurement time was reduced from approximately 7 min ± 2 (min) (manual) to 1 min (AUTO). Cochlear parameters in mm (mean ± SD) for R1, R2 and AUTO, respectively, were A-value: 9.00 ± 0.40, 8.98 ± 0.40 and 9.16 ± 0.36; B-value: 6.81 ± 0.34, 6.71 ± 0.35 and 6.70 ± 0.40; H-value: 3.98 ± 0.25, 3.85 ± 0.25 and 3.76 ± 0.22; and the mean CDLoc-length: 35.64 ± 1.70, 35.20 ± 1.71 and 35.47 ± 1.87. AUTO CDLOC measurements were not significantly different compared to R1 and R2 (H0: Rx CDLOC = AUTO CDLOC: p = 0.831, p = 0.242, respectively), and the calculated intraclass correlation coefficient (ICC) for CDLOC was 0.9 (95% CI: 0.85, 0.932) for R1 vs. AUTO; 0.90 (95% CI: 0.85, 0.932) for R2 vs. AUTO; and 0.893 (95% CI: 0.809, 0.935) for R1 vs. R2. Conclusions: We observed excellent inter-rater reliability, a high agreement of outcomes, and reduced execution time using the AUTO method.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Reference46 articles.

1. The length of the organ of Corti in man;Hardy;Am. J. Anat.,1938

2. Correlative study of sensory cell density and cochlear length in humans;Janisch;Hear. Res.,1987

3. Computer-aided three-dimensional reconstruction: A method of measuring temporal bone structures including the length of the cochlea;Takagi;Ann. Otol. Rhinol. Laryngol.,1989

4. In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays;Ketten;Ann. Otol. Rhinol. Laryngol. Suppl.,1998

5. Three-dimensional tonotopic mapping of the human cochlea based on synchrotron radiation phase-contrast imaging;Li;Sci. Rep.,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3