Abstract
The simulation of the energy consumptions in an hourly regime is necessary in order to perform calculations on residential buildings of particular relevance for volume or for architectural features. In such cases, the simplified methodology provided by the regulations may be inadequate, and the use of software like EnergyPlus is needed. To obtain reliable results, usually, significant time is spent on the meticulous insertion of the geometrical inputs of the building, together with the properties of the envelope materials and systems. Less attention is paid to the climate database. The databases available on the EnergyPlus website refer to airports located in rural areas near major cities. If the building to be simulated is located in a metropolitan area, it may be affected by the local heat island, and the database used as input to the software should take this phenomenon into account. To this end, it is useful to use a meteorological model such as the Weather Research and Forecasting (WRF) model to construct an appropriate input climate file. A case study based on a building located in the city center of Rome (Italy) shows that, if the climatic forcing linked to the heat island is not considered, the estimated consumption due to the cooling is underestimated by 35–50%. In particular, the analysis and the seasonal comparison between the energy needs of the building simulated by EnergyPlus, with the climatic inputs related to two airports in the rural area of Rome and with the inputs provided by the WRF model related to the center of Rome, show discrepancies of about (i) WRF vs. Fiumicino (FCO): Δ = −3.48% for heating, Δ = 49.25% for cooling; (ii) WRF vs. Ciampino (CIA): Δ = −7.38% for heating, Δ = +35.52% for cooling.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Reference58 articles.
1. Guidelines accompanying Commission Delegated Regulation (EU) No 244/2012 of 16 January 2012 supplementing Directive 2010/31/EU of the European Parliament and of the Council on the energy performance of buildings by establishing a comparative methodology framework for calculating cost-optimal levels of minimum energy performance requirements for buildings and building elements;Off. J. Eur. Union,2012
2. Directive 2002/91/EC of the European Parliament and of the Council of 16 December 2002 on the energy performance of buildings;Off. J. Eur. Union,2002
3. D.Lgs 19 agosto 2005, n. 192. Implementation of Directive 2002/91/EC on the energy performance of buildings
http://www.gazzettaufficiale.it/eli/id/2005/09/23/005G0219/sg
4. Heading towards the nZEB through CHP+HP systems. A comparison between retrofit solutions able to increase the energy performance for the heating and domestic hot water production in residential buildings
Cited by
62 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献