Effect of Unbalanced and Non-Linear Loads on Operation of the Turbogenerator of a Distributed Generation Unit

Author:

Bulatov Yuri1ORCID,Kryukov Andrey23,Suslov Konstantin24ORCID

Affiliation:

1. Department of Energy, Bratsk State University, 665730 Bratsk, Russia

2. Department of Power Supply and Electrical Engineering, Irkutsk National Research Technical University, 664074 Irkutsk, Russia

3. Department of Transport Electric Power, Irkutsk State Transport University, 664074 Irkutsk, Russia

4. Department of Hydropower and Renewable Energy, National Research University “Moscow Power Engineering Institute”, 111250 Moscow, Russia

Abstract

The article presents a description of models and results of research on separate and joint effects of unbalanced and non-linear loads on the operation of a lower-power synchronous generator. The modeling of the generator included automatic regulators of excitation and rotor speed. For our studies, we used computer models built in the MATLAB environment and the Fazonord package, as well as a physical model of a low-power synchronous generator. The simulation results attested to the occurrence of the following negative effects: there was a noticeable negative sequence current, the generator began to emit higher harmonics into the network, and the amplitude of forced oscillations of the excitation current increased. The presence of these effects can lead to additional mechanical vibrations of the rotor, accelerated wear of the equipment, and loss of stability. To ensure that low-power generators can operate in the presence of unbalance and harmonic distortion, it is necessary to limit their load. The maximum phase current difference, which must not exceed 12% of the nominal current, can be used as a criterion. Furthermore, when distributed generation units serve non-linear and unbalanced loads, it is necessary to implement special measures to protect the generating equipment: the use of direct current links, the use of harmonic filters, the installation of generator protections limiting negative sequence current, the use of automatic excitation current limitation, etc.

Funder

Conducting applied scientific research

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Investigation of an Unsymmetrically Loaded High Power Synchronous Generator;2024 23rd International Symposium on Electrical Apparatus and Technologies (SIELA);2024-06-12

2. Coordinated management of electricity storages and distributed generation plant with predictive controllers in a power supply system with reduced electricity quality;Power engineering: research, equipment, technology;2024-01-11

3. Introductory chapter: effects of power quality problems on energy efficiency of power systems;Energy Efficiency of Modern Power and Energy Systems;2024