Abstract
As lower-limb exoskeleton and prostheses are developed to become smarter and to deploy man–machine collaboration, accurate gait recognition is crucial, as it contributes to the realization of real-time control. Many researchers choose surface electromyogram (sEMG) signals to recognize the gait and control the lower-limb exoskeleton (or prostheses). However, several factors still affect its applicability, of which variation in the loads is an essential one. This study aims to (1) investigate the effect of load variation on gait recognition; and to (2) discuss whether a lower-limb exoskeleton control system trained by sEMG from different loads works well in multi-load applications. In our experiment, 10 male college students were selected to walk on a treadmill at three different speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h) with four different loads (L0 = 0, L20 = 20%, L30 = 30%, L40 = 40% of body weight, respectively), and 50 gait cycles were performed. Back propagation neural networks (BPNNs) were used for gait recognition, and a support vector machine (SVM) and k-nearest neighbor (k-NN) were used for comparison. The result showed that (1) load variation has significant effects on the accuracy of gait recognition (p < 0.05) under the three speeds when the loads range in L0, L20, L30, or L40, but no significant impact is found when the loads range in L0, L20, or L30. The least significant difference (LSD) post hoc, which can explore all possible pair-wise comparisons of means that comprise a factor using the equivalent of multiple t-tests, reveals that there is a significant difference between the L40 load and the other three loads (L0, L20, L30), but no significant difference was found among the L0, L20, and L30 loads. The total mean accuracy of gait recognition of the intra-loads and inter-loads was 91.81%, and 69.42%, respectively. (2) When the training data was taken from more types of loads, a higher accuracy in gait recognition was obtained at each speed, and the statistical analysis shows that there was a substantial influence for the kinds of loads in the training set on the gait recognition accuracy (p < 0.001). It can be concluded that an exoskeleton (or prosthesis) control system that is trained in a single load or the parts of loads is insufficient in the face of multi-load applications.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献