Author:
Zhang Xiaorong,Li Haibo,Li Yinghua,Guo Fei,Yang Zhongxin,Bai Jianing
Abstract
To understand characteristics of on-line oxidation-reduction potential (ORP) in a subsurface wastewater infiltration system (SWIS) under different intermittent influent conditions, ORP among five matrix depths at wet-dry ratios (Rwds) of 2:1, 1:1 and 1:2 with a hydraulic load of 0.10 m3·(m2·d)−1 were monitored. Results showed that the optimal Rwd for the SWIS was 1:1. In that case, ORP at 40 and 65 cm depths changed significantly, by 529 mV and 261 mV, respectively, from the inflow period to the dry period, which was conducive to the recovery of the oxidation environment. It was concluded that ORP varied nonlinearly in strongly aerobic and hypoxic environment. Wastewater was fed into the SWIS at 80 cm and dissolved oxygen diffused at the initial period of one cycle. As a consequence, ORP at 65 cm increased with water content increasing. However, ORP at 40 and 95 cm displayed inverse trends. Moreover, results showed that ORP decreased with Fe2+ and Mn2+ increasing under aerobic conditions (p < 0.05) because Fe2+ and Mn2+ moved with wastewater flow. Effluent met reuse requirements and no clogging was found in the SWIS during the operation.
Funder
National Natural Science Foundation of China
Shenyang Science and Technology Bureau
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献