Intraprocedure Artificial Intelligence Alert System for Colonoscopy Examination

Author:

Hsu Chen-Ming123,Hsu Chien-Chang4ORCID,Hsu Zhe-Ming4,Chen Tsung-Hsing23,Kuo Tony2

Affiliation:

1. Department of Gastroenterology and Hepatology, Taoyuan Chang Gung Memorial Hospital, Taoyuan 333, Taiwan

2. Department of Gastroenterology and Hepatology, Linkou Chang Gung Memorial Hospital, Taoyuan 333, Taiwan

3. College of Medicine, Chang Gung University, Taoyuan 333, Taiwan

4. Department of Computer Science and Information Engineering, Fu-Jen Catholic University, New Taipei 242, Taiwan

Abstract

Colonoscopy is a valuable tool for preventing and reducing the incidence and mortality of colorectal cancer. Although several computer-aided colorectal polyp detection and diagnosis systems have been proposed for clinical application, many remain susceptible to interference problems, including low image clarity, unevenness, and low accuracy for the analysis of dynamic images; these drawbacks affect the robustness and practicality of these systems. This study proposed an intraprocedure alert system for colonoscopy examination developed on the basis of deep learning. The proposed system features blurred image detection, foreign body detection, and polyp detection modules facilitated by convolutional neural networks. The training and validation datasets included high-quality images and low-quality images, including blurred images and those containing folds, fecal matter, and opaque water. For the detection of blurred images and images containing folds, fecal matter, and opaque water, the accuracy rate was 96.2%. Furthermore, the study results indicated a per-polyp detection accuracy of 100% when the system was applied to video images. The recall rates for high-quality image frames and polyp image frames were 95.7% and 92%, respectively. The overall alert accuracy rate and the false-positive rate of low quality for video images obtained through per-frame analysis were 95.3% and 0.18%, respectively. The proposed system can be used to alert colonoscopists to the need to slow their procedural speed or to perform flush or lumen inflation in cases where the colonoscope is being moved too rapidly, where fecal residue is present in the intestinal tract, or where the colon has been inadequately distended.

Funder

National Science and Technology Council of the Republic of China, Taiwan

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3