Effects of Periodontal Splints on Biomechanical Behaviors in Compromised Periodontal Tissues and Cement Layer: 3D Finite Element Analysis

Author:

Liu YuchenORCID,Fang Ming,Zhao Ruifeng,Liu Hengyan,Tian Min,Zhong Sheng,Bai ShizhuORCID

Abstract

Background: In this study, we evaluated the effect of periodontal splints made from different materials on the stress distributions in compromised periodontal tissues and cement layers, using a computer simulation of mastication. Methods: Twenty-five 3D models were created for a segment of mandibular teeth with different periodontal splints bilaterally extended to the canines. The models were divided into five groups according to the different materials and thicknesses (mm) of the splints: the non-splinted group, PEEK 0.7 group, PEEK 1.0 group, FRC group, and titanium group. Each group was subdivided based on five bone loss levels. Tooth 41 of each model was subjected to vertical and oblique (θ = 45°) static loads of 100 N, respectively, onto the incisal edge. The von Mises stresses and maximum principal stress were analyzed using Abaqus software. Results: Oblique loading resulted in higher stresses on periodontal tissues, cement layers, and splints than those caused by vertical loading. The lower the supporting bone level, the greater the stress difference between the splinted groups and the non-splinted group. In model 133,331, with severe bone loss, the maximum von Mises stress values on the alveolar bone in tooth 41 under oblique loading dramatically decreased from 406.4 MPa in the non-splinted group to 28.62 MPa in the PEEK group and to 9.59 MPa in the titanium group. The four splinted groups presented similar stress distributions in periodontal tissues. The lowest stress level on the splint was observed in the PEEK 0.7 group, and the highest stress level was transferred to the cement layer in this group. Stress concentrations were primarily exhibited at the connectors near the load-carrying area. Conclusions: The tested splinted groups were all effective in distributing the loads on periodontal tissues around splinted teeth with similar patterns. Using splinting materials with low elastic moduli reduced the stress concentration at the splint connectors, whereas the tensile stress concentration was increased in the cement layer. Thus, the use of adhesive cement with a higher elastic modulus is recommended when applying less rigid PEEK splints.

Funder

Shaanxi Key Research and Development Program

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3