99mTc-MAG3 Diuretic Renography: Intra- and Inter-Observer Repeatability in the Assessment of Renal Function

Author:

Sachpekidis Christos1ORCID,Schepers Robin1,Marti Monika1,Kopp-Schneider Annette2ORCID,Alberts Ian1,Keramida Georgia3,Afshar-Oromieh Ali1,Rominger Axel1

Affiliation:

1. Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland

2. Department of Biostatistics, German Cancer Research Center, 69120 Heidelberg, Germany

3. Department of Nuclear Medicine, Royal Brompton and Harefield NHS Foundation, London SW36NP, UK

Abstract

The aim of the present study is to evaluate the intra- and inter-observer agreement in assessing the renal function by means of 99mTc-MAG3 diuretic renography. One hundred and twenty adults were enrolled in the study. One experienced and one junior radiographer processed the renograms twice by assigning manual and semi-automated regions of interest. The differential renal function (DRF, %), time to maximum counts for the right and left kidney (TmaxR-TmaxL, min) and time to half-peak counts (T1/2, min) were calculated. The Bland–Altman analysis (bias±95% limits of agreement), Lin’s concordance correlation coefficient and weighted Fleiss’ kappa coefficient were used to assess agreement. Based on the Bland–Altman analysis, the intra-observer repeatability results for the experienced radiographer using the manual and the semi-automated techniques were 0.2 ± 2.6% and 0.3 ± 6.4% (DRF), respectively, −0.01 ± 0.24 and 0.00 ± 0.34 (TmaxR), respectively, and 0.00 ± 0.26 and 0.00 ± 0.33 (TmaxL), respectively. For the junior radiographer, the respective results were 0.5 ± 5.0% and 0.8 ± 9.4% (DRF), 0.00 ± 0.44 and 0.01 ± 0.28 (TmaxR), and 0.01 ± 0.28 and −0.02 ± 0.44 (TmaxL). The inter-observer repeatability for the manual method was 0.6 ± 5.0% (DRF), −0.10 ± 0.42 (TmaxR) and −0.05 ± 0.38 (TmaxL), and for the semi-automated method −0.2 ± 9.1% (DRF), 0.00 ± 0.31 (TmaxR) and −0.05 ± 0.40 (TmaxL). The weighted Fleiss’ kappa coefficient for the T1/2 assessments ranged between 0.85–0.97 for both intra- and inter-observer repeatability with both methods. These findings suggest a very good repeatability in DRF assessment with the manual method—especially for the experienced observer—but a less good repeatability with the semi-automated approach. The calculation of Tmax was also operator-dependent. We conclude that reader experience is important in the calculation of renal parameters. We therefore encourage reader training in renal scintigraphy. Moreover, the manual tool seems to perform better than the semi-automated tool. Thus, we encourage cautious use of automated tools and adjunct validation by manual methods where possible.

Publisher

MDPI AG

Reference20 articles.

1. Diuresis Renography in Equivocal Urinary Tract Obstruction;Testa;BJU Int.,1978

2. Consensus on diuresis renography for investigating the dilated upper urinary tract. Radionuclides in Nephrourology Group. Consensus Committee on Diuresis Renography;Aurell;J. Nucl. Med.,1996

3. Guidelines for standard and diuretic renogram in children;Gordon;Eur. J. Nucl. Med. Mol. Imaging,2011

4. SNMMI Procedure Standard/EANM Practice Guideline for Diuretic Renal Scintigraphy in Adults With Suspected Upper Urinary Tract Obstruction 1.0;Taylor;Semin. Nucl. Med.,2018

5. Renal clearance determination with one blood sample: Improved accuracy and universal applicability by a new calculation principle;Bubeck;Semin. Nucl. Med.,1993

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3