A Comparison of 68Ga-PSMA PET/CT-Based Split Renal Function with 99mTc-MAG3 Renography in Patients with Metastatic Castration-Resistant Prostate Carcinoma Treated with 177Lu-PSMA

Author:

Gabela Lerato12,Mkhize Thokozani12,Hadebe Bawinile12,Harry Lerwine12,Nxasana Thembelihle12,Ndlovu Nontobeko12,Pillay Venesen12,Masikane Sphelele12,Patel Maryam12,Nyakale Nozipho Elizabeth3,Vorster Mariza12ORCID

Affiliation:

1. Department of Nuclear Medicine, College of Health Sciences, University of KwaZulu Natal, Private Bag X54001, Durban 4001, South Africa

2. Inkosi Albert Luthuli Central Hospital, Durban 4001, South Africa

3. Department of Nuclear Medicine, Sefako Makgatho Health Science University, Pretoria 0208, South Africa

Abstract

Background: Physiological PSMA expression in the cells of the proximal renal tubules and consecutive radiopharmaceutical binding and retention could potentially lead to radioligand-therapy-induced nephrotoxicity. Thus, patients with metastatic castration-resistant prostate cancer undergo 99mTc-Mercaptoacetyltriglycine (MAG3) renal scintigraphy to assess kidney function and to exclude renal obstruction as part of their workup for PSMA-targeted radioligand therapy (RLT). 99mTc-MAG-3 renal scintigraphy often requires an additional visit to the nuclear medicine department and patients spend 30–90 min in the department, which is inconvenient and takes up camera time. In addition, the patients are subjected to a baseline 68Ga-PSMA PET/CT to assess for PSMA-positive disease prior to targeted radioligand therapy. The aim of this retrospective cross-sectional study was to compare 99mTc-MAG-3-based split renal function (SRF) with 68Ga-PSMA-derived SRF. Methods: This retrospective cross-sectional study included 28 patients with histologically proven metastatic castration-resistant prostate cancer (mCRPC) who received 177Lu-PSMA617. A comparison between the split renal function using 68Ga-PSMA PET/CT and the 99mTc-MAG-3-derived split renal function was carried out in 56 kidneys (n = 56). The SRF on 68Ga-PSMA was calculated using the volume and the average standard uptake value (SUVmean) within each VOI calculated as previously described by Roser et al.: SRF = (VOLUMEright) ∗ SUVmeanright/(VOLUMEright ∗ SUVmeanright + VOLUMEleft ∗ SUVmeanleft). Paired tests and correlation coefficients were used to compare 68Ga-PSMA and 99mTc-MAG-3. A visual comparison of kidney morphology on both studies was also performed. Results: The median SRF of the right kidney was 49.9% (range: 3–91%) using 68Ga-PSMA PET/CT and 50.5% (range: 0–94%) with 99mTc-MAG3 scintigraphy. Notably, there was a strong correlation between SRF measurements obtained from PSMA and 99mTcMAG3, with a Pearson correlation coefficient of 0.957 (p < 0.001). Both 99mTc-MAG3 and 68Ga-PSMA PET/CT studies identified morphological renal abnormalities; there were nine hydronephrotic kidneys, four shrunken kidneys and one obstructed kidney, and there was a strong positive correlation between 68Ga-PSMA kidney morphology and 99mTcMAG3 renal scintigraphy kidney morphology, with a correlation coefficient of 0.93. Conclusions: PSMA-derived split function demonstrated a high correlation with renal function assessed on diuretic 99mTc-MAG3 renograms. PET-derived split renal function may, therefore, be considered an alternative to diuretic renogram-based split function. Furthermore, both 99mTc-MAG3 and 68Ga-PSMA PET/CT studies identified morphological renal abnormalities such as hydronephrosis, shrunken and obstructed kidneys. This correlation underscores the potential utility of 68Ga-PSMA imaging as a valuable tool for assessing kidney morphology as an alternative to renogram split function in clinical practice.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3