Investigating the Sensitivity of Low-Cost Sensors in Measuring Particle Number Concentrations across Diverse Atmospheric Conditions in Greece and Spain

Author:

Kosmopoulos Georgios1,Salamalikis Vasileios2,Wilbert Stefan3ORCID,Zarzalejo Luis F.4ORCID,Hanrieder Natalie3,Karatzas Stylianos5,Kazantzidis Andreas1ORCID

Affiliation:

1. Laboratory of Atmospheric Physics, Department of Physics, University of Patras, GR 26500 Patras, Greece

2. NILU—Norwegian Institute for Air Research, P.O. Box 100, 2027 Kjeller, Norway

3. Institute of Solar Research, German Aerospace Center (DLR), Paseo de Almería 73, 04001 Almería, Spain

4. Renewable Energy Division, CIEMAT Energy Department, Avenida Complutense, 40, 28040 Madrid, Spain

5. Civil Engineering Department, University of Patras, GR 26500 Patras, Greece

Abstract

Low-cost sensors (LCSs) for particulate matter (PM) concentrations have attracted the interest of researchers, supplementing their efforts to quantify PM in higher spatiotemporal resolution. The precision of PM mass concentration measurements from PMS 5003 sensors has been widely documented, though limited information is available regarding their size selectivity and number concentration measurement accuracy. In this work, PMS 5003 sensors, along with a Federal Referral Methods (FRM) sampler (Grimm spectrometer), were deployed across three sites with different atmospheric profiles, an urban (Germanou) and a background (UPat) site in Patras (Greece), and a semi-arid site in Almería (Spain, PSA). The LCSs particle number concentration measurements were investigated for different size bins. Findings for particles with diameter between 0.3 and 10 μm suggest that particle size significantly affected the LCSs’ response. The LCSs could accurately detect number concentrations for particles smaller than 1 μm in the urban (R2 = 0.9) and background sites (R2 = 0.92), while a modest correlation was found with the reference instrument in the semi-arid area (R2 = 0.69). However, their performance was rather poor (R2 < 0.31) for coarser aerosol fractions at all sites. Moreover, during periods when coarse particles were dominant, i.e., dust events, PMS 5003 sensors were unable to report accurate number distributions (R2 values < 0.47) and systematically underestimated particle number concentrations. The results indicate that several questions arise concerning the sensors’ capabilities to estimate PM2.5 and PM10 concentrations, since their size distribution did not agree with the reference instruments.

Funder

European Union’s Horizon Europe Research and Innovation Programme

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry