Author:
Mohd Noor Sam Muhamad Arif Ihsan,Jin Zhenhu,Oogane Mikihiko,Ando Yasuo
Abstract
Magnetic flux leakage (MFL) testing is a method of non-destructive testing (NDT), whereby the material is magnetized, and when a defect is present, the magnetic flux lines break out of the material. The magnitude of the leaked magnetic flux decreases as the lift-off (distance from the material) increases. Therefore, for detection at high lift-off, a sensitive magnetic sensor is required. To increase the output sensitivity, this paper proposes the application of magnetic tunnel junction (MTJ) sensors in a bridge circuit for the NDT of reinforced concrete at high lift-off. MTJ sensors were connected to a full-bridge circuit, where one side of the arm has two MTJ sensors connected in series, and the other contains a resistor and a variable resistor. Their responses towards a bias magnetic field were measured, and, based on the results, the sensor circuit sensitivity was 0.135 mV/mT. Finally, a reinforced concrete specimen with a 1 cm gap in the center was detected. The sensor module (with an amplifier and low pass filter circuits) could determine the gap even at 50 cm, suggesting that MTJ sensors have the potential to detect defects at high lift-off values and have a promising future in the field of NDT.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献