Experimental Demonstration of Compact Polymer Mass Transfer Device Manufactured by Additive Manufacturing with Hydrogel Integration to Bio-Mimic the Liver Functions

Author:

Narendran Ganesan1,Walunj Avdhoot2ORCID,Kumar A. Mohan3,Jeyachandran Praveen4,Awwad Nasser S.5ORCID,Ibrahium Hala A.6,Gorji M. R.7,Perumal D. Arumuga1ORCID

Affiliation:

1. Micro and Nanofluidics Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Suruthkal, Mangaluru 575025, India

2. Department of Mechanical Engineering, Mahatma Phule Krishi Vidyapeeth, Rahuri 413722, Maharashtra, India

3. Department of Clinical Microbiology, All India Institute of Medical Sciences, Mangalagiri 522503, Andhra Pradesh, India

4. Department of Mechanical Engineering, National Institute of Technology Karnataka, Suruthkal, Mangaluru 575025, India

5. Department of Chemistry, College of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia

6. Department of Biology, College of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia

7. Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium

Abstract

In this paper, we designed and demonstrated a stimuli-responsive hydrogel that mimics the mass diffusion function of the liver. We have controlled the release mechanism using temperature and pH variations. Additive manufacturing technology was used to fabricate the device with nylon (PA-12), using selective laser sintering (SLS). The device has two compartment sections: the lower section handles the thermal management, and feeds temperature-regulated water into the mass transfer section of the upper compartment. The upper chamber has a two-layered serpentine concentric tube; the inner tube carries the temperature-regulated water to the hydrogel using the given pores. Here, the hydrogel is present in order to facilitate the release of the loaded methylene blue (MB) into the fluid. By adjusting the fluid’s pH, flow rate, and temperature, the deswelling properties of the hydrogel were examined. The weight of the hydrogel was maximum at 10 mL/min and decreased by 25.29% to 10.12 g for the flow rate of 50 mL/min. The cumulative MB release at 30 °C increased to 47% for the lower flow rate of 10 mL/min, and the cumulative release at 40 °C climbed to 55%, which is 44.7% more than at 30 °C. The MB release rates considerably increased when the pH dropped from 12 to 8, showing that the lower pH had a major impact on the release of MB from the hydrogel. Only 19% of the MB was released at pH 12 after 50 min, and after that, the release rate remained nearly constant. At higher fluid temperatures, the hydrogels lost approximately 80% of their water in just 20 min, compared to a loss of 50% of their water at room temperature. The outcomes of this study may contribute to further developments in artificial organ design.

Funder

Ministry of Education in KSA

Publisher

MDPI AG

Subject

Bioengineering

Reference55 articles.

1. Artificial and Bioartificial Liver Support;Pless;Organogenesis,2007

2. Acute-on-Chronic Liver Failure: An Update;Hernaez;Gut,2017

3. Indication of Liver Transplantation Following Amatoxin Intoxication;Ganzert;J. Hepatol.,2005

4. Management of Decompensated Cirrhosis;Mansour;Clin. Med. J. R. Coll. Physicians Lond.,2018

5. Liver Transplantatation- an Overview;Rai;Indian J. Surg.,2013

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3