Rate of Change of Liver Iron Content by MR Imaging Methods: A Comparison Study

Author:

Venkatakrishna Shyam Sunder B.ORCID,Otero Hansel J.,Ghosh AdarshORCID,Khrichenko Dmitry,Serai Suraj D.

Abstract

Objective: Magnetic resonance imaging (MRI) can accurately quantify liver iron concentration (LIC), eliminating the need for an invasive liver biopsy. Currently, the most widely used relaxometry methods for iron quantification are R2 and R2*, which are based on T2 and T2* acquisition sequences, respectively. We compared the rate of change of LIC as measured by the R2-based, FDA-approved commercially available third-party software with the rate of change of LIC measured by in-house analysis using R2*-relaxometry-based MR imaging in patients undergoing follow-up MRI scans for liver iron estimation. Methods: We retrospectively included patients who had undergone serial MRIs for liver iron estimation. The MR studies were performed on a 1.5T scanner; standard multi-slice, multi-echo T2- and T2*-based sequences were acquired, and LIC was estimated. The comparison between the rate of change of LIC by R2 and R2* values was performed via correlation coefficients and Bland–Altman difference plots. Results: One hundred and eighty-nine MR abdomen studies for liver iron evaluation from 81 patients (male: 38; female: 43) were included in the study. Fifty-nine patients had two serial scans, eighteen patients had three serial scans, three patients had four serial scans, and one patient had five serial scans. The average time interval between the first and last scans for each patient was 13.3 months. The average rates of change of LIC via R2 and R2* methods were −0.0043 ± 0.0214 and −0.0047 ± 0.012 mg/g per month, respectively. There was no significant difference in the rate of change of LIC observed between the two methods. Linearity between the rate of change of LIC measured by R2 (LIC R2) and R2* (LIC R2*) was strong, showing a correlation coefficient of r = 0.72, p < 0.01. A Bland–Altman plot between the rate of change of the two methods showed that the majority of the plotted variables were between two standard deviations. Conclusion: There was no significant difference in the rate of change of LIC detected between the R2 method and the R2* method that uses a gradient echo (GRE) sequence acquired with breath-hold. Since R2* is relatively faster and less prone to motion artifacts, R2*-derived LIC is recommended for iron homeostasis follow-up in patients with liver iron overload.

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging

Reference31 articles.

1. The roles of iron in health and disease

2. R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods

3. Evaluation and Treatment of Transfusional Iron Overload in Children

4. Hereditary hemochromatosis;Crownover;Am. Fam. Physician,2013

5. Diagnosis of hemochromatosis;Powell;Semin. Gastrointest. Dis.,2002

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3