Abstract
This study used model experiments and numerical simulations to investigate the backlayering length of a vehicle-blocked tunnel fire. The experimental setup included two types of obstacles (low obstacles and high obstacles), as well as three configurations: no obstacles, one side with a car obstacle, and two sides with a car obstacle. If there were vehicles on one side of a lane, it would have little effect on the elongation of the backlayer length. When there were vehicles on both sides of a lane, the elongation of the backlayer length was greatly reduced. In addition, the effects of the vehicular blockage ratio and blockage configuration on the properties of the backlayering length were investigated. We created Pattern A, where fire is was in the center, and Pattern B, where fire was on the side of the tunnel. In Pattern A, almost all obstacles could be approximated using the formula. When the vehicle blockage ratio of a single lane was small, an approximation formula for Pattern B was applicable. However, if the distance between stationary vehicles on the upstream side of the fire source was small, the backlayering length could have been longer than in the case with no vehicular blockage.
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Reference29 articles.
1. PIARC Fire and Smoke Control,1999
2. Temperature Characteristics of Backlayering Thermal Fumes in a Tunnel Fire
3. Emergency operation of ventilation for the Kanetsu road tunnel;Mizuno;Proceedings of the 5th International Symposium on the Aerodynamics and Ventilation of Vehicle Tunnels,1985
4. An optimal control with disturbance estimation for the emergency ventilation of a longitudinally ventilated road tunnel;Mizuno
5. Controllability of longitudinal air flow in transversely ventilated tunnels with multiple ventilation divisions;Mizuno;Proceedings of the First International Conference on Safety in Road and Rail Tunnels,1992
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献