Hazard Evaluation of Indoor Air Quality in Bank Offices

Author:

Saidin Hamidi12,Razak Azli Abd1ORCID,Mohamad Mohd Faizal1,Ul-Saufie Ahmad Zia3ORCID,Zaki Sheikh Ahmad4ORCID,Othman Nor’azizi4

Affiliation:

1. School of Mechanical Engineering, College of Engineering, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia

2. Department of Occupational Safety and Health, Ministry of Human Resources Malaysia, Presint 1, Putrajaya 62000, Wilayah Persekutuan Putrajaya, Malaysia

3. School of Mathematical Sciences, College of Computing, Information and Media, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia

4. Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Wilayah Persekutuan Kuala Lumpur, Malaysia

Abstract

IAQ is a crucial factor affecting the health, comfort, and productivity of workers, particularly those working in enclosed spaces like bank offices. This study aimed to evaluate the IAQ of a bank office’s operational area and vault by analyzing concentrations of CO2, TVOC, PM10, and PM2.5, as well as temperature, relative humidity, and air movement. Two different ventilation systems were compared to assess their impact on IAQ. The acquired data were statistically analyzed using mean comparison t-tests and hazard ratio analysis. The results revealed that indoor concentrations of PM2.5 and CO2 significantly contribute to the total hazard ratio, indicating the need to reduce their levels below reference values. The study also found that the ventilation system significantly affects indoor air quality, and concentrations of TVOC, CO2, PM10, and PM2.5 in the air are considerable. Significantly, the study found that bank offices with split unit air-conditioners had the highest mean CO2 levels, indicating poor ventilation. Overall, the study reveals that the building, activities, and ventilation in bank offices have a profound influence on IAQ parameters, primarily PM2.5 and CO2. Further research is required to formulate strategies for enhancing IAQ in these settings.

Funder

UTM

Universiti Teknologi Malaysia

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3