Abstract
Cable-stayed bridges have been widely used in large-span bridge engineering because of their large span capacity and novel structure. The frequent traffic of vehicles transporting flammable and explosive materials has increased the incidence of bridge fires. After being burned, the cable-stayed bridge will suffer from varying degrees of damage, which affects its performance. Therefore, mechanical analysis and evaluation of the fire-damaged cable-stayed bridge are necessary. Due to the development of technology, the structural analysis of cable-stayed bridges has gradually shifted from experimental methods to numerical simulation or artificial intelligence methods, and from local performance research to holistic research. In this paper, a fire accident in the Sifangtai Bridge in Harbin, China, is taken as a case study. Finite element software and damage theory calculation methods were used, and the static and dynamic performances of the bridge under the condition of cable fire damage were analyzed. The results show that the variation of cable force during the movement of vehicle load along the bridge is relatively small, within the range of 7% to 12%. The fusing of the upper cables of the bridge tower has the greatest impact on the deflection of the beam, while the fusing of lower cables has the same impact on the deflection of the entire bridge as the undamaged state. Near the fused cables, cable forces change significantly, increasing by over 20%. As the degree of damage increases, the increase in deflection of the beam becomes more pronounced. The impact of different degrees of cable damage on the dynamic performance of cable-stayed bridges is reflected in quantitative changes. As the degree of cable damage and the amount of fusing increase, the change in structural frequency becomes more pronounced. This paper not only provides technical support and a theoretical basis for the performance analysis of cable-stayed bridges damaged by fire, but it also improves the research content of combining static and dynamic performance, which provides important reference values for similar research in the future.
Funder
Heilongjiang Provincial Colleges and Universities
Scientific Research Fund of Institute of Engineering Mechanics, China Earthquake Administration
Heilongjiang Province Ecological Environment Protection Research Project
Reference48 articles.
1. Numerical Simulation of Ultimate Bearing Capacity of Cables for a Cable-Stayed Bridge under Tanker Fire;Ning;Steel Constr.,2012
2. Study on Thermal and Structural Behavior of a Cable-Stayed Bridge under Potential Tanker Truck Fires;Liu;Appl. Mech. Mater.,2012
3. Safety of Cable-Supported Bridges during Fire Hazards;Gong;J. Bridg. Eng.,2016
4. Zhang, L., Wei, Y., and Au, F.T.K. (2014, January 9–12). Mechanical Properties of Prestressing Steel at Elevated Temperature and after Cooling. Proceedings of the 23rd Australasian Conference on the Mechanics of Structures and Materials (ACMSM23), Bryon Bay, NSW, Australia.
5. Experimental Investigation on Mechanical Properties of Grade 1670 Steel Wires under and after Elevated Temperature;Du;Adv. Steel Constr.,2023