Thermal Performance of Residential Roofs in Malaysia: Experimental Study Using an Indoor Solar Simulator

Author:

Mohd Ashhar Muhamad Zahin1,Lim Chin Haw1ORCID

Affiliation:

1. Solar Energy Research Institute, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia

Abstract

Previous researchers have detailed the problems in measuring the thermal resistance value of a whole roof assembly under hot conditions due to the uncertainty of the outdoor environment. Currently, no established method exists to experimentally investigate an entire thermal roof performance under a steady-state condition. This article details the properties of the indoor solar simulator and the research methods undertaken to measure the thermal resistance value of roof assembly. The indoor solar simulator utilizes 40 halogen bulbs to accurately replicate sun radiation. Thermocouples and heat flux sensors are installed at several locations on the roof assembly to quantify the heat transmission occurring through it. The thermal resistance value is determined by adding up the average difference in temperature across the external and internal roof surfaces and dividing the total amount by the total of all averaged heat fluxes. Subsequently, this study investigates the thermal efficiency of residential roof assemblies that comprise various insulation materials frequently employed in Malaysia, including stone wool, mineral glass wool, reflective bubble foil insulation, and radiant barriers. The analysis showed that the roof configurations with bubble foil reflective insulation produce superior thermal resistance values when coupled with enclosed air space or mass insulation, with thermal resistance values ranging between 2.55 m2K/W and 3.22 m2K/W. It can be concluded that roof configurations with bubble foil reflective insulation resulted in high total thermal resistance and passed the minimum thermal resistance value of 2.5 m2K/W under the Malaysian Uniform Building By-Law 38 (A) requirements. Furthermore, the radiant barrier produced a high thermal resistance value of 2.50 m2K/W when installed parallel to a 50 mm enclosed air space, emphasising the crucial function of an enclosed air space next to a reflective foil to resist the incoming heat radiation. The findings from this research can help building professionals determine the optimum insulation for residential building roofs in Malaysia.

Funder

University Kebangsaan Malaysia

Publisher

MDPI AG

Reference35 articles.

1. Energy Commission (2023, September 15). Malaysia Energy Statistics Handbook 2020, Available online: https://www.st.gov.my/en/contents/files/download/116/Malaysia_Energy_Statistics_Handbook_20201.pdf.

2. (2014). Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings—Code of Practice (Standard No. MS 1525:2014).

3. Effects of solar photovoltaic panels on roof heat transfer;Dominguez;Sol. Energy,2011

4. Zhang, Y., Sun, H., Long, J., Zeng, L., and Shen, X. (2022). Experimental and Numerical Study on the Insulation Performance of a Photo-Thermal Roof in Hot Summer and Cold Winter Areas. Buildings, 12.

5. Modeling of cool roof heat transfer in tropical climate;Zingre;Renew. Energy,2015