Are Implant Threads Important for Implant Stability? An In Vitro Study Using Low-Density Polyurethane Sheets

Author:

Comuzzi Luca1,Tumedei Margherita2,Di Pietro Natalia34ORCID,Romasco Tea34ORCID,Montesani Lorenzo5,Piattelli Adriano6,Covani Ugo7

Affiliation:

1. Independent Researcher, 31015 Conegliano, Italy

2. Department of Medical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy

3. Department of Medical, Oral and Biotechnological Sciences, “G. d’Annunzio” University of Chieti-Pescara, 66013 Chieti, Italy

4. Center for Advanced Studies and Technology—CAST, “G. d’Annunzio” University of Chieti-Pescara, 66013 Chieti, Italy

5. Independent Researcher, 00187 Rome, Italy

6. School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy

7. Tuscan Dental Institute, Versilia General Hospital, 55041 Lido di Camaiore, Italy

Abstract

Different strategies are known to improve implant primary stability (PS) and the bone-to-implant contact in post-extractive conditions, such as the macro-geometry of screws and apical threads, which can enhance the mechanical characteristics. In any case, the role of the apical area design in maintaining or improving the PS, especially in low-quality bone, still remains unclear. Thus, the present study aimed at evaluating in vitro the Insertion Torque (IT), Removal Torque (RT), and Resonance Frequency Analysis (RFA) of different implant apical threads in a cylindrical (EE) and in three conical implants (T3, TAC, Intra-lock) inserted in simulated post-extraction conditions on low-density polyurethane foams of 10 and 20 pounds per cubic foot (PCF), with and without the addition of a cortical sheet of 30 PCF in density. The IT, RT, and RFA values of all the implants tested were directly proportional to the polyurethane density and to the presence of the cortical sheet, but TAC and Intra-lock implants, which had the latest-generation thread design, always showed significantly higher values (e.g., IT: 18.6 and 18.6 Ncm, RT: 10.8 and 13.7 Ncm, RFA mean: 46 and 43 ISQ, in the 20 PCF density with the cortical sheet for TAC and Intra-lock, respectively). In particular, TAC implants also reached the highest RFA values in the lowest-density foam (19 ISQ). In conclusion, the present in vitro study demonstrated that TAC and Intra-lock apical designs and macro-geometries could play a key role in determining the PS and the polyurethane-implant contact in simulated post-extraction conditions in low-density artificial bone.

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3